PRODUCTS AND SOLUTIONS
Cross Match® L SCAN 1000T is a
1000 ppi high-resolution, lightweight,
compact fingerprint livescan system
for use in desktop, portable or cabinet
configurations. The industry group,
SWGFAST, Scientific Working Group
on Friction Ridge Analysis, Study and
Technology, strongly recommended at
the ANSI/NIST 2005 Workshop
meeting, an image quality standard of
1000 ppi for ten-print and palm print
images, and Cross Match is leading
the way with the L SCAN 1000T.
Third-level detail, such as the shape
of fingerprint ridges and sweat pores,
can be of utmost importance in
making an identification. Although
today.s modern AFIS systems reach
search accuracies of 99 percent, it is
still the responsibility of the fingerprint
examiner to determine the correct
identity from a list of possible
candidates. While 500 ppi fingerprint
images are standard and perfectly
suited for automatic searching,
sorting candidates based on thirdlevel
detail requires another level of
image contents. Those details
become clearly visible with the
superb resolution and outstanding
image quality of the L SCAN 1000T
Finger/ID flats livescan system.
The L SCAN 1000T combines solid
performance, real-time display and
instant quality checks to produce
crystal clear and crisp images. The
L SCAN 1000T is lightweight, and
compact for configuration flexibility,
and the smart buttons make it easy
to use.
Download L SCAN 1000T Product Brochure
- Easy and intuitive, even in unattended/self-service environments
- Crystal View technology with true 1000 ppi scan resolution
- Flash Capture for real-time roll, scan, and preview on screen with a single platen
- Takes ten rolled fingers, all flat fingers and thumbs
- No stitching of images, no moving parts, solid, stable.
| System components |
 |
Scanner
L SCAN 1000T and L SCAN 1000TvS
with silicone membrane for superior
capture of fingerprints from dry and
damaged skin; IEEE 1394 (FireWire)
interface cable; external power supply
unit (AC cable with country-specific
plug); CaptureEssentials driver
software; footswitch and transport
travel case (optional)
|
| Image quality certification |
|
Certified to FBI Standard CJIS-RS-0010, Appendix F “IAFIS Image Quality Specifications for Scanners”, category Livescan Systems 500/1000 ppi and category Identification Flats Systems 500 ppi
|
| Power supply & consumption |
|
External power supply, wide range
input: AC 100V-240V, 50/60 Hz output: DC 18.5 - 19.95 V, 50/60 Hz, max. 3A, max. 75 VA operation
|
| Scanner PC interface |
|
IEEE 1394 (FireWire) OHCI interface
|
| Scanned fingers |
|
Rolled and flat single fingers, flat four fingers, flat two thumbs, format supports the capture of ID flats according to FBI specifications
|
| Capture platen |
|
Single platen for rolled prints, flats and thumbs; rolled prints captured in the middle of the platen no separation into sections, no stitching of image
|
| Silicone membrane |
|
Available with silicone membrane to achieve best dry finger image quality
|
| Scanner control |
|
Smart Button Easy Control, illuminated function keys and status lamp
|
| Rolled prints capturing |
|
Perfect Roll, variable speed, auto direction, real-time quality assurance checks includes correct roll checks
|
| Flat prints capturing |
|
Flash Capture True-1K, full area simultaneous capture, full upright orientation of fingers
|
| Flats timing |
|
< 0.5 seconds, at 500 ppi and at 1000 ppi
|
| Rolled prints format |
|
1.6” x 1.5” (41 x 38 mm)
|
| Flats prints format |
|
max. 3.2” x 3.0” (81.2 x 76.2 mm)
|
| Scanner resolutions |
|
1000 pixels-per-inch (ppi) in 1000 ppi mode and 500 pixels-per-inch (ppi) in 500 ppi mode, software selectable
|
| Capture display |
|
True live-display of single and multiple finger impressions on the PC screen
|
| Image feature mapping |
|
Crystal View True-1K technology, fully optimized handling of all quality related parameters during digital image conditioning, lowest noise and best geometric accuracy plus finest feature representation
|
| Software |
|
Available in levels for OEMs, system integrators and end users, running under MS Windows 2000/XP
|
| Scanner weight |
|
15.2 lbs (6.9 kg)
|
| Scanner size |
|
11.8” x 10.0” x 5.5” (299 mm x 255 mm x 141 mm)
|
| Scanner workspace |
|
Flat over the entire platen area, water protected and factory sealed, protection flap over the capture platen area
|
| Operating conditions |
|
Indoor use, 50-95°F (10-35°C), 10-80% relative humidity, non-condensing, no direct sunlight exposure.
|
| Examples |
|
Capture of criminal fingerprints (Law Enforcement Booking), capture of applicant fingerprints (Civil Background Check), capture of fingerprints at ports of entry (Border Control), capture of fingerprints from visa applicants (Embassy and Consulate), capture of fingerprints from asylum seekers and refugees.
|
All Cross Match products come with the Cross Match Limited Warranty. The Cross Match Enhanced Limited Warranty is recommended for 24x7 customer care service and next business day replacement of hardware. Maintenance support upon the expiration of the Enhanced Limited Warranty period is available subject to execution of the Cross Match standard Maintenance Plan. For more information, please contact the Cross Match Sales Department.
Back to Top
|
 |